Conditions |
Dimensional
tolerance2) |
Total radial
run-out tolerance |
Total axial
run-out tolerance |
Ra6) | Displacement
of outer ring |
|
– | – | – | µm | – | ||
For non-split housings only | Rotating outer ring load | |||||
Heavy loads on bearings in thin-walled housings,
heavy peak loads (P > 0,1 C) |
P7 | IT6/2 | IT6 | 3,2 | Cannot be displaced | |
Normal to heavy loads (P > 0,05 C) | N7 | IT6/2 | IT6 | 3,2 | Cannot be displaced | |
Light and variable loads (P = 0,05 C) | M7 | IT6/2 | IT6 | 3,2 | Cannot be displaced | |
Direction of load indeterminate | ||||||
Heavy peak loads | M7 | IT6/2 | IT6 | 3,2 | Cannot be displaced | |
Normal to heavy loads (P > 0,05 C),
axial displacement of outer ring unnecessary |
K75) | IT6/2 | IT6 | 3,2 | In most cases,
cannot be displaced |
|
For non-split housings
and split housings |
Direction of load indeterminate | |||||
Light to normal loads (P = 0,1 C),
axial displacement of outer ring desirable |
J7 | IT6/2 | IT6 | 3,2 | In most cases,
can be displaced |
|
Stationary outer ring load | ||||||
Loads of all kinds | H73) | IT6/2 | IT6 | 3,2 | Can be displaced | |
Light to normal loads (P = 0,1 C)
with simple working conditions |
H83) | IT6/2 | IT6 | 3,2 | Can be displaced | |
Thermal expansion of the shaft | G74) | IT6/2 | IT6 | 3,2 | Can be displaced | |