ISO tolerance classes for housings

Housing
Bearing
Housing bore diameter deviations
Nominal bore diameter
Outside diameter tolerance
Tolerance classes1)
D
ΔDmp H11 H7 J7 K7 M7 N7
over incl. max min low high low high low high low high low high low high
mm μm μm
10 18 0 -8 0 +110 0 +18 -8 +10 -12 +6 -18 0 -23 -5
18 30 0 -9 0 +130 0 +21 -9 +12 -15 +6 -21 0 -28 -7
30 50 0 -11 0 +160 0 +25 -11 +14 -18 +7 -25 0 -33 -8
50 80 0 -13 0 +190 0 +30 -12 +18 -21 +9 -30 0 -39 -9
80 120 0 -15 0 +220 0 +35 -13 +22 -25 +10 -35 0 -45 -10
120 150 0 -18 0 +250 0 +40 -14 +26 -28 +12 -40 0 -52 -12
150 180 0 -25 0 +250 0 +40 -14 +26 -28 +12 -40 0 -52 -12
180 250 0 -30 0 +290 0 +46 -16 +30 -33 +13 -46 0 -60 -14
250 315 0 -35 0 +320 0 +52 -16 +36 -36 +16 -52 0 -66 -14
315 400 0 -40 0 +360 0 +57 -18 +39 -40 +17 -57 0 -73 -16
400 500 0 -45 0 +400 0 +63 -20 +43 -45 +18 -63 0 -80 -17
500 630 0 -50 0 +440 0 +70 - - -70 0 -96 -26 -114 -44
630 800 0 -75 0 +500 0 +80 - - -80 0 -110 -30 -130 -50
800 1 000 0 -100 0 +560 0 +90 - - -90 0 -124 -34 -146 -56
1 000 1 250 0 -125 0 +660 0 +105 - - -105 0 -145 -40 -171 -66
1 250 1 600 0 -160 0 +780 0 +125 - - -125 0 -173 -48 -203 -78
1 600 2 000 0 -200 0 +920 0 +150 - - -150 0 -208 -58 -242 -92

The symbols used in the tolerance table are explained in the following:
D
= nominal housing bore diameter
ΔDmp = deviation of the mean outside diameter from the nominal in a single plane
  1. 1) All ISO tolerance classes are valid with the envelope requirement (such as H7) in accordance with ISO 14405-1:2010.