Housing
|
Bearing
|
Housing bore diameter deviations
|
Nominal bore diameter
|
Outside diameter tolerance
|
Tolerance classes1)
|
D
|
ΔDmp
|
H11 |
H7 |
J7 |
K7 |
M7 |
N7 |
over |
incl. |
max |
min |
low |
high |
low |
high |
low |
high |
low |
high |
low |
high |
low |
high |
mm |
μm |
μm |
10 |
18 |
0 |
-8 |
0 |
+110 |
0 |
+18 |
-8 |
+10 |
-12 |
+6 |
-18 |
0 |
-23 |
-5 |
18 |
30 |
0 |
-9 |
0 |
+130 |
0 |
+21 |
-9 |
+12 |
-15 |
+6 |
-21 |
0 |
-28 |
-7 |
30 |
50 |
0 |
-11 |
0 |
+160 |
0 |
+25 |
-11 |
+14 |
-18 |
+7 |
-25 |
0 |
-33 |
-8 |
50 |
80 |
0 |
-13 |
0 |
+190 |
0 |
+30 |
-12 |
+18 |
-21 |
+9 |
-30 |
0 |
-39 |
-9 |
80 |
120 |
0 |
-15 |
0 |
+220 |
0 |
+35 |
-13 |
+22 |
-25 |
+10 |
-35 |
0 |
-45 |
-10 |
120 |
150 |
0 |
-18 |
0 |
+250 |
0 |
+40 |
-14 |
+26 |
-28 |
+12 |
-40 |
0 |
-52 |
-12 |
150 |
180 |
0 |
-25 |
0 |
+250 |
0 |
+40 |
-14 |
+26 |
-28 |
+12 |
-40 |
0 |
-52 |
-12 |
180 |
250 |
0 |
-30 |
0 |
+290 |
0 |
+46 |
-16 |
+30 |
-33 |
+13 |
-46 |
0 |
-60 |
-14 |
250 |
315 |
0 |
-35 |
0 |
+320 |
0 |
+52 |
-16 |
+36 |
-36 |
+16 |
-52 |
0 |
-66 |
-14 |
315 |
400 |
0 |
-40 |
0 |
+360 |
0 |
+57 |
-18 |
+39 |
-40 |
+17 |
-57 |
0 |
-73 |
-16 |
400 |
500 |
0 |
-45 |
0 |
+400 |
0 |
+63 |
-20 |
+43 |
-45 |
+18 |
-63 |
0 |
-80 |
-17 |
500 |
630 |
0 |
-50 |
0 |
+440 |
0 |
+70 |
- |
- |
-70 |
0 |
-96 |
-26 |
-114 |
-44 |
630 |
800 |
0 |
-75 |
0 |
+500 |
0 |
+80 |
- |
- |
-80 |
0 |
-110 |
-30 |
-130 |
-50 |
800 |
1 000 |
0 |
-100 |
0 |
+560 |
0 |
+90 |
- |
- |
-90 |
0 |
-124 |
-34 |
-146 |
-56 |
1 000 |
1 250 |
0 |
-125 |
0 |
+660 |
0 |
+105 |
- |
- |
-105 |
0 |
-145 |
-40 |
-171 |
-66 |
1 250 |
1 600 |
0 |
-160 |
0 |
+780 |
0 |
+125 |
- |
- |
-125 |
0 |
-173 |
-48 |
-203 |
-78 |
1 600 |
2 000 |
0 |
-200 |
0 |
+920 |
0 |
+150 |
- |
- |
-150 |
0 |
-208 |
-58 |
-242 |
-92 |
The symbols used in the tolerance table are explained in the following:
D
|
= |
nominal housing bore diameter
|
ΔDmp
|
= |
deviation of the mean outside diameter from the nominal in a single plane
|