Conditions | Shaft
diameter |
Dimensional
tolerance1) |
Total radial
run-out tolerance2) |
Ra
|
– | mm | – | – | µm
|
Rotating inner ring load or direction of load indeterminate | ||||
Light and variable loads | ≤ 10 | k5 | IT5/2
|
0,4 |
(P ≤ 0,05 C) | > 10 to 25 | k6 | IT5/2 | 0,8 |
> 25 to 100 | m6 | IT5/2 | 0,8 | |
Normal to heavy loads | ≤ 25 | k5 | IT5/2 | 0,4 |
(0,05 C < P ≤ 0,1 C) | > 25 to 60 | m6 | IT5/2 | 0,8 |
> 60 to 100 | n6 | IT5/2 | 0,8 | |
> 100 to 400 | p63) | IT5/2 | 1,6
|
|
Heavy to very heavy loads | > 50 to 100 | n63) | IT5/2 | 0,8
|
(P > 0,1 C) | > 100 to 200 | p63) | IT5/2 | 1,6
|
> 200 | r63) | IT5/2 | 1,6
|
|
Stationary inner ring load | ||||
Easy axial displacement of
the inner ring on the shaft desirable |
g6 | IT5/2 | 1,6
|
|
Easy axial displacement of
the inner ring on the shaft unnecessary |
h6 | IT5/2 | 1,6
|
|